Joint Tape Led to Joint Cracks

Q: We used self-adhering glass-mesh joint tape with ready-mixed joint compound, and now we’re seeing cracks in the joints. What’s going on?




A: Imagine my surprise after a nine-year hiatus to return to a topic that I thought had been long resolved but apparently is still alive and well! Had I missed a new development while off promoting the miracle mineral? Did I not know what I thought I knew? To ensure I knew wherefrom I spoke before responding to this query, I did a little digging, and after pulling up several technical data sheets on the Internet and speaking to some manufacturers’ technical support people, I both confirmed what I thought I knew and added a couple of tidbits that were new to me.




First, what I confirmed: The technical data sheets posted on the Internet recommend using self-adhering glass-mesh joint tape only with setting-type joint compound, better known in the trade as “hot mud.” Hot mud contains ingredients that cause the compound to harden when mixed with water, much in the way Plaster of Paris does; this reaction creates heat, which no doubt led to the moniker “hot mud.” Because setting-type joint compound sets up by a chemical reaction relatively quickly (or in some cases, really, really quickly), it does not sit wet long enough on the self-adhering glass mesh tape to attack the adhesive. Ready-mixed joint compound, or regular drying-type joint compound that sets up as the added water returns to the atmosphere, stays wet for some time, as it is entirely dependent on temperature and humidity to achieve proper hardness. And under less than ideal drying conditions, that can be long enough for the water to attack the adhesive holding the tape to the surface and loosen the bond, which in turn results in cracks in the joint when the building inevitably moves. So, according to all the manufacturers’ literature, paper tape is the material to use when working with drying-type joint compound.




There are both self adhering and non-sticky glass mesh tapes out there. The non-sticky variety is most commonly attached with staples to “blue board” in a veneer plaster application, after which the joints are first coated with a base coat plaster mix. This much I knew. What I didn’t know is that setting type joint compound—that’s our friend “hot mud”—can be also used to cover the joints in a veneer plaster application (best to check the manufacturer’s recommendations before trying this!). What I also didn’t know is that paper joint tape can be used in a veneer plaster application in lieu of glass-mesh tape. In the past, all the information I had seen on veneer plaster mentioned only the glass mesh tape, so I was mildly surprised to pick up on this factoid.




This led to a little more schooling on paper tape for me: It turns out that paper tape has some advantages in both joint compound and veneer plaster applications. Paper tape, though a bit more cumbersome and slower to work with in some applications, makes for a stronger joint that is less likely to crack. At first, this struck me as odd. Everyone knows fiberglass is far stronger than paper, so surely it should make for a better, stronger joint. But fiberglass tape also stretches more than paper tape, which can result in cracking if the material the tape is embedded in is not particularly strong or flexible. Setting-type joint compound and plaster are usually strong enough to hold up without cracking over joints; however, paper tape resists movement and ensures against cracks even when using these materials. I also learned that there is the standard weight of paper tape, which apparently most everyone uses, but there is also a heavy-duty version that meets ASTM C475, which requires especially robust properties of the material.




Q: What can you tell me about spray-in foam insulation in really general terms?


A:  Spray-in insulation materials are typically two-component polyurethane products that are field-applied using a volumetric displacement pump that combines part A and part B in a one-to-one ratio. They can be applied between framing members both vertically and horizontally in thickness from 1 to 12 inches, offering R-values (depending upon specific type and thickness) of 6.0 to 73.8. The material is applied in passes no less than half an inch and no more than 2 1/2 inches thick to achieve the specified thickness. Excess material is shaved off once set using a variety of tools.




Interior installations may be required to be covered with an approved thermal barrier, such as 1/2-inch thick gypsum board. An approved ignition barrier may be required in crawl spaces and attics, depending on access to the space.




Spray polyurethane insulation may also serve as a Class II vapor retarder, and half an inch of the material has been shown to be air-impermeable when tested per ASTM E 283.




As always, check local building code requirements and manufacturer’s literature and specifications before using.




Lee G. Jones is AWCI’s director of technical services. Send your questions to [email protected], or call him directly at (703) 538.1611.

Browse Similar Articles

You May Also Like

When I give presentations to engineers, I like to ask the question, “How many of you have ever designed something that cannot physically be built? Raise your hand if you have.”
In the building construction industry, we all have to work within the building codes—the rules for how buildings are constructed. But how do the codes get written and adopted into law, and
AWCI's Construction Dimensions cover

Renew or Subscribe Today!